Sign In | Join Free | My udpf.com
China Wuhan Rising Electric Co., Ltd. logo
Wuhan Rising Electric Co., Ltd.
Active Member

6 Years

Home > CT PT Testing Equipment >

0.05 Class 300A Standard Current Transformer With 1 Year Warranty

Wuhan Rising Electric Co., Ltd.
Contact Now

0.05 Class 300A Standard Current Transformer With 1 Year Warranty

  • 1
  • 2
  • 3

Brand Name : RISING

Model Number : RSHL-200A

Certification : ISO CE

Place of Origin : China

MOQ : 1 SET

Payment Terms : L/C, L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 500 SET PER Month

Packaging Details : Wooden package

Power : Electronic

Capacity : 5VA

Standard current ratio : 0.1A~10000A/5A, 1A

Usage : Instrument

Size : 280mm×60mm×60mm

Warranty : 1 Year

Contact Now

RSHL-300A CT VT Testing Equipment High Accuracy 0.05 class 300A Standard Current Transformer

Product Description

  • Purpose

It can be used as a standard instrument for the verification of grade current transformers or for other precision current measurement

The function of the transformer is to reduce the ac voltage and the large current in proportion to the value that can be directly measured by the instrument, so as to facilitate the direct measurement by the instrument, and at the same time to provide power for relay protection and automatic devices.The transformer can measure the voltage, current and electric energy of the primary system in coordination with the measuring instrument and measuring device.Together with relay protection and automatic devices, it can constitute electrical protection and automatic control for various faults of the power grid.It is part of the component of transformer integrated test bench.

  • Conditions of use

Ambient temperature:0°C -- +40°C; Relative humidity should be greater than 80%

  • Use and maintenance
  • Please be careful not to seriously collide with the machine due to its epoxy resin casting.The machine should be moisture-proof and soiled.And the surface of the instrument should be wiped with a clean cloth before the test to prevent creepage along the surface
  • In the process of measuring the current,do not allow sudden interruption in the current,so easy to cause remanence in the iron core,easy to cause a large error in the measurement.
  • Special attention should be paid to the fact that in the process of measurement,the secondary coil loop should be firmly grounded,and no open circuit should be opened to avoid the generation of high voltage,so as not to harm people.
Technical Parameters

Rated Primary Current 5,10,25,50,100,200,300A

Rated Secondary Current 5A

Rated Power Factor =1.0

Rated Capacity 5VA

Rated Voltage 5000/√3V

Rated Frequency 50/150Hz

The Environmental conditions of the Verification:

Temperature 22°C ; Relative Humidity: 52%

Test result:

Insulation Resistance >100

Power Frequency withstand Voltage:10kV/1min

Polarity: -

Conclusion and explanation:0.05 Class

Note: before delivery, the rated power frequency withstand voltage (10kV) has been tested.

After delivery, the test shall be conducted at 80% of the rated value to do testing.


Product Tags:

secondary load tester

      

secondary load instrument

      
Best 0.05 Class 300A Standard Current Transformer With 1 Year Warranty wholesale

0.05 Class 300A Standard Current Transformer With 1 Year Warranty Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Wuhan Rising Electric Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)